DIgSILENT Load Flow Analysis

Digsilent Power Flow Analysis

This article shows the step by step process on how to run DIgSILENT Load Flow Analysis. This will help engineers to practice on how to run load flow analysis on DIgSILENT Power Factory Software.

Sample Network Model

You can setup a simple network model and perform a load-flow simulation for the following Network Model:

Network Model in DIgSILENT-Power Factory Software
Network Model in DIgSILENT-Power Factory Software

Creating a New Project

In order to setup a network model first you need to create a New Project. New Project Can be created as: File>>New>Project as below:

Creating a New Project
Creating a New Project

Provide a suitable name for the project.

Provide a suitable name for the project
Provide a suitable name for the project

Set-up Network Model

Grid

This window is the drawing-broad where you can create your network model.

Grid: Drawing Board
Grid: Drawing Board

Placing the Power System Components

First, place all the components in the DIgSILENT PF drawing-board and construct the network model graphically.

Hints:
Placing Busbars/ Terminals:

  • First click on the busbar element in the drawing toolbar, and then place the element by clicking on the area where you want to place it in the drawing-board.

Placing the Transmission Lines and Transformer elements:

  • You can connect a Transmission Line or a Transformer element by first selecting the object from the drawing toolbar and then left click on terminals that you wish to connect the element.
  • The method above connects an orthogonal line directly between the two terminals. To create a more complicated route, you can left click at various ’way-points’ in the drawing-board after selecting the first terminal.

Setting-up the Parameters for Power System Devices/ Objects

The next step is to set-up the parameters for the various devices in the network model. You need to double-click on each device to set the parameters. The “Basic Data” Tab allows you to set-up the “Type”. Each component must have “Type” and type specifies the general parameters of components.

Setting the Parameters for Synchronous Generators

Double-click on the Synchronous Generator Element to open the parameter page. When you navigated to the “Basic Data” Tab, click on Type, and then click on “New Project Type”.

Setting up Generator Type
Setting up Generator Type

Specify the MVA capacity of the generator and voltage at the generator terminals in the “Basic Data” Tab. You don’t need to change any data in the “Load Flow” Tab unless the generator reactance/resistance data is specified in the datasheet.

Synchronous Machine Type
Synchronous Machine Type

Once the parameters for the generator type are specified, the next step is to specify the operating details for the synchronous generator. Now navigate to the synchronous generator (Not Type!) “Load Flow” Tab.

For the Slack Bus Generator (Bus 1) Specify the Following:

Specify the Generator Bus
Specify the Generator Bus – Slack Bus

For the synchronous generator (Bus 4) at the PV bus, specify the following. Make sure you specify the type for the Synchronous Generator as the PV bus.

Specify the Generator Bus - PV Bus
Specify the Generator Bus – PV Bus

Setting the Parameters for the Busbar

Double-click on the Busbar Element to open the parameter page. Set the nominal voltage for the busbar (It is not required to specify a Type for the busbar).

Specify Type of Busbar
Specify Type of Busbar

The following nominal voltages applies to the test system:

Setting the Parameters for the Transmission Lines

Double-click on the Transmission Line Element to open the parameter page. Specify the following details in the “Basic Data” Tab of the “Line Type”. Please note that you need to specify the line parameters in Ω/km, therefore if the parameters are specified in “per unit” you should convert them to Ω/km.

Specify Line Type
Specify Line Type

Specify the Susceptance in the Load Flow tab.

Specify the Susceptance in the Load Flow tab

Important: If the total value of the line parameters is specified in the datasheet, assume that value as the Ω/km specification. Therefore you can specify the line length as 1 km in the “Basic Data” Tab of the line.

Setting the Parameters for the Transformer

Double-click on the Transformer Element to open the parameter page. Specify the following data in the “Basic Data” tab of the transformer type.

Setting the Parameters for the Transformer
Setting the Parameters for the Transformer

Specifying the Tap settings for the Transformer

First setup the tap changer configuration in the “Load Flow” Tab in the “Transformer Type”.

Then based on your tap requirement set the tap value at the transformer “Load Flow” Tab. If the tap setting is at the HV side and specifies as 0.975, the tap position should be -2 for the above tap specification.

Setting the Parameters for Loads

Double-click on the Load Element to open the parameter page. You can directly enter active and reactive power in the “Load Flow” tab in the general load. It is not necessary to specify any Type for the load.

Setting the Parameters for Loads
Setting the Parameters for Loads

Setting the Parameters for the Solar-PV

Double-click on the solar-PV model and then navigate to the “Basic Data” Tab. Then specify the following parameters:

Setting the Parameters for the Solar-PV
Setting the Parameters for the Solar-PV

Then navigate to the “Load Flow” Tab and specify the following:

Conducting a Load-Flow Simulation

Now you have specified all the data for the test system and next step is to run the load flow by clicking on Execute button.

Load Flow Calculation Sequence
Load Flow Calculation Sequence

Load-Flow Simulation Results

The output window will display the progress of the load flow simulation.

Load-Flow Simulation Report

The results of the load flow can be obtained from the result boxes next to the object. However in order to obtain complete system results you need to execute the following.

View Complete System Results
Output of Results
Output of Results

You can see the load-flow results in the output window:

Load Flow Results in Output Window
Load Flow Results in Output Window

Relevant Contents

Related Posts

protection coordination
ETAP
Chief Editor

Protection and Coordination Analysis

This article demonstrates the high level step by step procedure to perform the protection and coordination analysis in ETAP software. Below are the steps: Select protective devices models from editor Once the single line diagram and data entry is complete

Read More »
directional protection
Protection
Chief Editor

Directional Overcurrent Protection

Application Directional Overcurrent Protection is useful for all network components in which the direction of flow of power is likely to change, notably in the instance of a short circuit between phases or of an earthing fault (single phase fault).

Read More »
arc flash
Arc Flash
Chief Editor

Arc Flash Mitigation With Maintenance Mode

Introduction To Maintenance Mode The Arc Flash Mitigation with Maintenance Mode provides a method to reduce clearing time of arc flash energy. A circuit breaker equipped with Maintenance Mode can improve safety by providing a simple and reliable method to

Read More »
Tur-Gov
Electrical Equipment
Chief Editor

Generator Turbine Governor Control

Introduction The generator turbine governor control regulates rotational speed in response to changing load conditions. The governor output signal manipulates the position of a steam inlet valve or nozzles which in turn regulates the steam flow to the turbine. Turbine-generator

Read More »
short circuit
General
Chief Editor

X/R Ratio in Low-Voltage Short Circuit Studies

This article discusses about the importance of X/R ratio in low voltage short circuit studies. Introduction In some short circuit studies, the X/R ratio is ignored when comparing the short circuit rating of the equipment to the available fault current

Read More »
harmonic frequency scan
General
Chief Editor

Harmonic Analysis Methods

Harmonic analysis methods help engineers to calculate system harmonic levels resulting from harmonic sources on the system. This also requires a knowledge of the harmonic source characteristics and a representation of the system frequency response characteristics. Below sections cover the

Read More »

Author Information

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *